Description
Specifications: | |
AC input voltage | 88~264VAC,Nominal 100-240VAC |
Input frequency | 47~63Hz |
Inrush current | 40A @230VAC, full load cold start |
Hold up time | 60ms@230 VAC,100% of rated maximum load |
Overload protection | 110%- 150% |
Over voltage protection | 110%-140% |
Operating temperature | -20 ~ 70°C, refer to output derating curve |
Safety standard | UL60950-1 |
EMC standard | EN55022 class B |
MTBF | 105 h at 25°C |
Withstand voltage | I/P-O/P:3KV, I/P-FG:1.5KV,1min |
Weight | 0.41Kg/pcs |
P/N |
Output |
Tol. |
R&N |
Effi. |
Load Regulation |
DC adjustment range |
SW-EPR-50-3.3 |
3.3V,10A |
3% |
80mV |
72% |
3% |
3.2~3.5V |
SW-EPR-50-5 |
5V,10A |
2% |
80mV |
78% |
2% |
4.75~5.5V |
SW-EPR-50-12 |
12V,4.2A |
1% |
120mV |
81% |
1% |
11.4~13.2V |
SW-EPR-50-24 |
24V,2.2A |
1% |
120mV |
84% |
1% |
22.8V~26.4V |
SW-EPR-50-48 |
48V,1.1A |
1% |
200mV |
86% |
1% |
45.6~52.8V |
Reviews