Description
| Specifications: | |
| AC input voltage | 88~264VAC,Nominal 100-240VAC |
| Input frequency | 47~63Hz |
| Inrush current | 40A @230VAC, full load cold start |
| Hold up time | 60ms@230 VAC,100% of rated maximum load |
| Overload protection | 110%- 150% |
| Over voltage protection | 110%-140% |
| Operating temperature | -20 ~ 70°C,refer to output derating curve |
| Safety standard | UL60950-1 |
| EMC standard | EN55022 class B |
| MTBF | 105 h at 25°C |
| Withstand voltage | I/P-O/P:3KV,I/P-FG:1.5KV,1min |
| Weight | 0.41Kg/pcs |
|
P/N |
Output |
Tol. |
R&N |
Effi. |
Load Regulation |
DC adjustment range |
|
SW-EPR-75-3.3 |
3.3V,15A |
3% |
80mV |
71% |
3% |
3.2~3.5V |
|
SW-EPR-75-5 |
5V,12A |
2% |
80mV |
76% |
2% |
4.75~5.5V |
|
SW-EPR-75-12 |
12V,6A |
1% |
120mV |
81% |
1% |
11.4~13.2V |
|
SW-EPR-75-24 |
24V,3.2A |
1% |
120mV |
85% |
1% |
22.8V~26.4V |
|
SW-EPR-75-48 |
48V,1.6A |
1% |
200mV |
86% |
1% |
45.6~52.8V |






Reviews